The Tens Unit Ultima 3T uses a microprocessor, which gives exact dial performance. The Ultima 3T Tens Unit's Microprocessor Benefits include an accurate Timer, and an accurate output of maximum, full strength power of 80ma. This Tens Unit is as accurate as a digital unit, yet easy to operate! Safety amplitude cap: Protects the Amplitude Knobs from accidental bumps or knob movements. The Ultima 3T Tens Unit's Electronic Muscle Stimulation is an internationally accepted and proven way of treating muscle injuries. The Ultima 3T Tens Unit works by sending electronic pulses to the muscle needing treatment; this causes the muscle to exercise passively. The Ultima 3T Tens Unit's Electronic Muscle Stimulation has a low frequency and this in conjunction with the square wave pattern allows direct work on muscle groupings. The Ultima 3T Tens Unit's Electronic Muscle Stimulation is widely used in hospitals and sports clinics for the treatment of muscular injuries and for the re-education of paralyzed muscles, to prevent atrophy in affected muscles and improving muscle tone and blood circulation.
Channels: Dual Channels, Isolated between channel
3 Modes:
1. Normal.
2. Modulation Mode: Pulse width is automatically varied in a cyclic pattern over an interval of nominally 4.0 Seconds.
3. Burst Mode: 7 pulses per burst / 2 bursts per second / 100 Hz internal frequency of burst.
Timer: 30 minute, 60 minute, Constant
Wave Form: Asymmetric biphasic square pulse
Amplitude: 0 to 15mA each channel, adjustable (500 ohm load)
Pulse Width: Variable, 60-250(uS) microseconds, adjustable.
Frequency: 2 to 150 Hz, adjustable. (Pulse Rate)
Max Charge: 20 micro coulombs per pulse.
Size: 31x64x92mm
Safety Amplitude Cap
Microprocessor Technology for precision dial performance
Ultima 3T Tens Unit One Year Manufacturer Warranty Ultima 3T Tens Unit System Includes: * Stimulator * Lead Wires * 4 Self-Stick Hypoallergenic Disposable Electrodes (sized 2" round) * 9V Battery * Hard Plastic Carrying Case * Instruction Booklet * Channel: Dual, isolated between channels Tens Unit Warnings: * Long term effects of chronic electrical stimulation are unknown. * Stimulation should not be applied over the carotid sinus nerves, particuarly in patients with a known sensitivity to the carotid sinus reflex. * Stimulation should not be applied over the neck or mouth. Severe spasm of the larygeal and pharyngeal muscles may occur and the contractions may be strong to close the airway or cause difficulty in breathing. * Stimulation should not be applied transthoracically in that the introduction of electrical current into the heart may cause cardiac arrhythmias. * Stimulation should not be applied transcerebrally. * Stimulation should not be applied over swollen, infected, or inflamed areas or skin eruptions. * Stimulation should not be applied over, or in proximity to, cancerous lesions. Ultima 3T Tens Unit Product Manual (Download PDF)Tens Ultima 3T Tens Unit ManualFAQDownload FAQ PDF
|